Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Year range
1.
Bauru; s.n; 2017. 85 p. ilus, tab, graf.
Thesis in Portuguese | LILACS | ID: biblio-880703

ABSTRACT

Na prática clínica, nota-se uma dificuldade em identificar a rigidez do sistema tímpano-ossicular decorrente da Otosclerose por meio dos métodos de avaliação rotineiramente empregados. Assim, as medidas de imitância acústica de banda larga podem fornecer mais informações sobre a condição do sistema tímpano-ossicular por avaliarem uma ampla faixa de frequência. O objetivo do estudo foi caracterizar as medidas de imitância acústica de banda larga com os estímulos tom puro e chirp em indivíduos com diagnóstico de Otosclerose submetidos à estapedectomia ou estapedotomia. Foram avaliados 40 indivíduos na faixa etária de 33 a 80 anos, totalizando 54 orelhas operadas e 22 orelhas não operadas. A avaliação audiológica foi realizada por meio da otoscopia, audiometria tonal liminar, logoaudiometria e imitanciometria. As medidas de imitância acústica de banda larga foram obtidas por meio do sistema de medidas Middle-Ear Power Analyzer MEPA3, versão 5.0 (Mimosa Acoustics), utilizando os estímulos tom puro e chirp. Os dados obtidos foram submetidos à análise estatística descritiva e inferencial, com nível de significância de 0,05. As orelhas com Otosclerose apresentaram maior absorvância em 750 Hz, uma tênue diminuição até 3000 Hz, acentuando-se a partir desta frequência. A magnitude da admitância foi maior na faixa de frequência de 1992 a 4008 Hz, assim como a magnitude da impedância foi maior nas frequências baixas com diminuição até 4008 Hz e aumento em 6000 Hz. Estas orelhas foram dominadas pela rigidez nos sons graves e médios, por resistência entre 3000 e 4008 Hz e a partir desta frequência pela massa. A fase da impedância foi maior em 258 Hz e o delay da reflectância (slope) apresentou uma variação de comportamento entre as frequências, não sendo possível caracterizar um padrão de resposta. Conclui-se que há diferenças nas medidas obtidas nas orelhas com Otosclerose submetidas à cirurgia, quando analisadas as frequências baixas e médias, o que demonstra o impacto positivo da intervenção cirúrgica na funcionalidade do sistema tímpano-ossicular.(AU)


In clinical practice, there is a difficulty in identifying the rigidity of the tympano-ossicular system resulting from Otosclerosis through the routinely employed evaluation methods. Thus, wideband acoustic immitance measurements can provide more information on the condition of the tympanic-ossicle system by evaluating a wide frequency range. This study aimed at characterizing the wideband acoustic immitance measurements with the pure tone and chirp stimuli in individuals diagnosed with Otosclerosis submitted to stapedectomy or stapedotomy. Forty individuals aged 33 to 80 years were evaluated, totaling 54 operated and 22 non-operated ears. Audiology assessment was performed through otoscopy, pure-tone audiometry, logoaudiometry and imitanciometry. Wideband acoustic immitance measurements were obtained using the Middle-Ear Power Analyzer (MEPA3), version 5.0 (Mimosa Acoustics), by means of pure tone and chirp stimuli. Data were submitted to descriptive and inferential statistical analysis, with a significance level of 0.05. The ears with Otosclerosis presented a greater absorbance in 750 Hz, a slight diminution until 3000 Hz, being accentuated from this frequency. The admittance magnitude was higher in the frequency range from 1992 to 4008 Hz, as well as the impedance magnitude was higher in the low frequencies with a decrease up to 4008 Hz and an increase in 6000 Hz. These ears were dominated by rigidity in the low and medium sounds, by resistance between 3000 and 4008 Hz, and from this frequency, by the mass. The impedance phase was higher at 258 Hz and the reflectance delay (slope) showed a behavioral variation between the frequencies, a response not being characterized. It can be concluded that there are differences in the measurements obtained in Otosclerosis ears submitted to surgery, when the low and medium frequencies were analyzed, which demonstrates the positive impact of the surgical intervention on the tympano-ossicle system.(AU)


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Aged , Aged, 80 and over , Audiometry/methods , Ear Ossicles/physiopathology , Ear, Middle/physiopathology , Otosclerosis/physiopathology , Acoustic Impedance Tests/methods , Analysis of Variance , Reference Values , Statistics, Nonparametric
2.
An. otorrinolaringol. mex ; 40(2): 85-92, mar.-mayo 1995. ilus, tab
Article in Spanish | LILACS | ID: lil-173939

ABSTRACT

Se exploraron con tomografía computada de alta resolución 60 oídos de 44 pacientes con malformaciones congénitas de los oídos externo y medio, valorando las alteraciones anatómicas según un criterio pre-establecido. Se establecen algunos parámetros para dar mayor objetividad a este análisis. Se encontrtó alteración bilateral en 26 pacientes y unilateral en 28. De los 60 oídos, 39 (65 por ciento) tenían atresia del conducto auditivo externo y 21 (35 por ciento) estenosis. El oído medio era de tamaño adecuado en 43 (72 por ciento) oídos inadecuado en 17 (28 por ciento). El trayecto del nervio facial se encontró normal en 39 (65 por ciento) y alterado en 21 (35 por ciento) oídos. La proporción de anomalías en el curso del nervio facial fue mucho mayor en los oídos con atresia, 19 de 39 (49 por ciento) que presentaban estenosis del conducto. Se propone una escala de puntuación para seleccionar a los candidatos a la cirugía, según el pronóstico funcional y riesgo


Subject(s)
Child, Preschool , Child , Adolescent , Adult , Humans , Male , Female , Cholesteatoma/diagnosis , Ear Canal/abnormalities , Ear Diseases/congenital , Facial Nerve/physiopathology , Incus/physiopathology , Ear/abnormalities , Ear/physiopathology , Ear Ossicles/physiopathology , Oval Window, Ear/physiopathology , Stapes/physiopathology , Tomography, Emission-Computed/methods
SELECTION OF CITATIONS
SEARCH DETAIL